Amphenol Network Solutions 600CB08 Load Center Panel

Additional information

Manufacturer

Your Price: $0.00
Add to Quote
tempest-customer-support

Questions? Ask our experts today.

Amphenol Network Solutions 600CB08 4RU Load Center Panel: high-current circuit breaker/fuse panel

Amphenol Network Solutions engineered its high-current circuit breaker/fuse panel specifically for load center distribution requirements in telecom operations and enterprises, providing both primary and secondary distribution with the capability of a GMT fuse panel – all in a single solution.

Amphenol Network Solutions engineered this innovative high-current circuit breaker/ fuse panel specifically to distribute power to network elements that draw between 60A to 80A of power, such as network routers, data servers, MCPAs or other standard equipment that would typically be supported by a battery distribution frame.

This next-generation panel provides the flexibility for both primary and secondary distribution, delivering the ampacity of a battery distribution frame, the capability and alarming of a GMT fuse panel, and the compact size of a high-current circuit breaker panel — all in a single solution.

Each of the 600A feeds provides power to eight high-current output positions and five GMT output positions, with a broad range of options to fit your requirements. Choose from field-replaceable circuit breakers (single-pole or double-pole) or TPC fuses. Holders are also available for installation of TPS/ TLS fuses with GMT indicators. Separate covers are required when using these fuse holders.

  • High-current capability – two 600A inputs
  • Fuse panel convenience – five 15A GMT fuses per input
  • High power-power distribution – eight 100A single pole positions per input
  • Handles single-pole, double-pole or triple-pole circuit breakers, standard-trip or mid-trip
  • Supports TPC, TPS and TLS fuses
  • Field configurable – bullet style connectivity:
    • Airpax-LEL or Carling CA1 standard breakers
    • Airpax-LMC or Carling CT1 mid-trip breakers
    • Telpower TPC fuse holders
    • CSI TFD fuse holders
  • Universal voltage applications – ±24 VDC and -48 VDC operation supported
  • Full alarming capability – panel and bay alarm indication
  • Industry compliant – UL, cUL and NEBS level 3
  • Rack mountable – Both 19″ and 23″ rack-mount capable
  • Nominal voltage: ±24 VDC and -48 VDC
  • Input rating: 600 A

Please refer to Data Sheet for complete specifications.

Applications include network routers, data servers, MCPAs, other standard equipment supported by BDFBs, and CO, data center, wireless, remotes, co-locates